Table 3 The analysis of the concentration number of particulate matter detected during the use of electrocautery knife at different locations.

From: Investigating surgical smoke in otolaryngology operating rooms

Detection time

Particulate matter size

Sampling location

Mean

Standard deviation

p-value

Beginning of the knife used

0.3 μm

Main knife range

4.83*105

1.51*106

0.061

Outside the operation table

4.97*104

8.70*104

0.5 μm

Main knife range

2.12*105

8.21*105

0.096

Outside the operation table

1.02*104

1.38*104

5.0 μm

Main knife range

1.80*103

4.58*103

0.054

Outside the operation table

3.91*102

4.67*102

5–10 min after beginning

0.3 μm

Main knife range

2.12*105

7.83*105

0.094

Outside the operation table

2.13*104

6.47*104

0.5 μm

Main knife range

9.96*104

3.60*105

0.083

Outside the operation table

6.48*103

1.82*104

5.0 μm

Main knife range

2.97*103

1.33*104

0.163

Outside the operation table

5.30*102

7.73*102

  1. Unit: particles/ft3.
  2. 0.05 < p < 0.1,*p < 0.05.