Table 4 Values obtained in PG, CZ and PZ regions of interest using ground truth and predicted masks. “mask” and “predicted” in the column headers refer to the ground truth and model output, respectively. T-test results between ground truth and predicted masks for PG, CZ, and PZ are reported in the right part of the table (based on segmentation results for the IMs using magnitude images as input).

From: Fully automated quantification of in vivo viscoelasticity of prostate zones using magnetic resonance elastography with Dense U-net segmentation

Map

Pixel values (average ± standard deviation)

T-test (significance at P<0.05)

PG mask

PG predicted

CZ mask

CZ predicted

PZ mask

PZ predicted

PG P-value

CZ P-value

PZ P-value

SWS

1.28 ± 0.39

1.35 ± 0.4

1.25 ± 0.32

1.36 ± 0.33

1.39 ± 0.22

1.28 ± 0.22

0.87

0.81

0.83

mag

33.1 ± 10.46

36.56 ± 11.05

29.6 ± 7.85

34.03 ± 8.31

43.21 ± 7.2

39.7 ± 7.29

0.83

0.78

0.85

\(\varphi\)

0.61 ± 0.19

0.63 ± 0.19

0.64 ± 0.17

0.66 ± 0.17

0.58 ± 0.09

0.56 ± 0.09

0.91

0.88

0.87