Table 4 The total maximum enthalpy change in KJ/mol for Re = 1000 at different activation energies.
Pr | k (W/(m K)) | E = 75,000 J/mol | E = 76,000 J/mol | E = 77,000 J/mol | E = 78,000 J/mol | E = 79,000 J/mol | E = 80,000 J/mol |
|---|---|---|---|---|---|---|---|
2.0000 | 0.59900 | 225.60 | 210.08 | 195.48 | 184.91 | 177.80 | 173.09 |
2.0000 | 0.69900 | 225.50 | 209.98 | 195.41 | 184.86 | 177.77 | 173.07 |
2.0000 | 0.79900 | 225.41 | 209.89 | 195.35 | 184.82 | 177.74 | 173.06 |
2.5000 | 0.59900 | 248.24 | 229.09 | 207.46 | 192.05 | 182.15 | 175.83 |
2.5000 | 0.69900 | 248.13 | 228.93 | 207.35 | 191.98 | 182.11 | 175.80 |
2.5000 | 0.79900 | 248.02 | 228.80 | 207.25 | 191.92 | 182.07 | 175.78 |
3.0000 | 0.59900 | 270.83 | 252.81 | 222.36 | 200.33 | 186.94 | 178.73 |
3.0000 | 0.69900 | 270.74 | 252.60 | 222.20 | 200.23 | 186.88 | 178.70 |