Table 2 Grid independent test average Nusselt number on hot surface at (Re = 200, Ri = 10, Da = 1e−3 λ = 5, φ = 0.04, Ha = 20, γ = 45, A = 0.15, N = 3).

From: MHD mixed convection and entropy generation of CNT-water nanofluid in a wavy lid-driven porous enclosure at different boundary conditions

Grid

Domain elements

Boundary elements

Time (sec)

Nuave

\(\left|Error\right|\%\)

\(\left|{\psi }_{min}\right|\)

Error \(\%\)

G1

3259

247

27

13.173

0.034794

G2

4917

307

29

13.181

0.06

0.034796

0.0057

G3

8521

453

36

13.154

0.205

0.034795

0.0028

G4

19,721

797

46

13.144

0.076

0.034826

0.089

G5

26,527

797

70

13.144

0

0.034838

0.0344

  1. Significant values are in bold.