Table 3 The detection result of automatic counting.
From: Rapid and automatic detection of micronuclei in binucleated lymphocytes image
BNCs | BNCsMN | MNi | |
|---|---|---|---|
Automated scoring | 2961 | 920 | 1564 |
Manual diagnosis | 2525 | 816 | 1154 |
Manual scoring | 2978 | 1029 | 1359 |
Total number of cells (5 categories) | 23,941 | ||
BNCs yield relative to manual scoring | 99.4% | ||
BNCsMN yield relative to manual scoring | 89.4% | ||