Table 5 Comparative results between FDTC and FDTCO.

From: Design and processor in the loop implementation of an improved control for IM driven solar PV fed water pumping system

Irradiation (W/m2)

Performance

FDTC

FDTCO

Current (A)

Flux (Wb)

Water flow rate (m3/s)

Current (A)

Flux (Wb)

Water flow rate (m3/s)

1000

7.764

1.2

0.009

6.15

1

0.01

700

7.27

1.2

0.0087

5.94

0.9

0.0089

500

6.7

1.2

0.0077

5.8

0.83

0.0079