Table 6 Flexural and tensile stiffness and failure load of the composite structure formed by different thicknesses of double-layer pavement under the action of a negative bending moment.

From: Static test research on steel bridge deck pavement structures paved by high-content hybrid fibre polymer concrete

Pavement thickness

70 mm

70 mm + 10 mm

70 mm + 20 mm

Flexural and tensile stiffness of the composite structure, in KN/mm)

18.000

20.769

24.167

Failure load, in KN

13.5

13.5

14.5