Table 2 The linear attenuation coefficients obtained in the present study using the computational and experimental methods compared to the results of similar studies.

From: Assessment of new composites containing polyamide-6 and lead monoxide as shields against ionizing photonic radiation based on computational and experimental methods

PbO wt%

Calculated by XMuDat (this study)

Experiments (this study)

Harish et al.14

Bagheri et al.15

Mahmoud et al.16

E = 662 (keV)

5

0.102

0.101 ± 0.035

0.0997

0.089

-

10

0.109

0.091 ± 0.032

0.114

0.102

0.105

20

0.123

0.130 ± 0.046

0.1264

0.119

-

50

0.196

0.140 ± 0.049

0.206

-

0.189

E = 59 (keV)

5

0.496

0.400 ± 0.140

-

-

-

10

0.800

0.605 ± 0.212

-

-

0.599

20

1.555

1.050 ± 0.369

-

-

-

50

5.130

4.050 ± 1.422

-

-

4.488