Table 4 Comparison of thermal insulation effect on the right side of D2 section.

From: Study on thermal insulation and seismic effect for fault-crossing tunnel in high geothermal area

Monitoring point

Compared with PC

Compared with PC highly damped composite structure

Compared with SFRC

PC highly damped composite structure

SFRC

SFRC highly damped composite structure

SFRC highly damped composite structure

SFRC highly damped composite structure

Vault

1.19%

− 32.90%

− 1.13%

− 2.34%

23.91%

Right spandrel

1.36%

− 32.49%

− 0.84%

− 2.23%

23.89%

Right sidewall

0.30%

− 29.56%

− 1.86%

− 2.16%

21.38%

Inverted arch

1.53%

− 24.99%

− 0.40%

− 1.97%

19.67%