Table 2 The comparation of the main-energy neutron fluences at the diamond position measured using the diamond detector and fission chamber/associated alpha particle method, and the comparation of the proportions of the low-energy neutrons measured with the diamond detector and the EJ-309 liquid scintillator.
From: Simultaneous measurement of energy spectrum and fluence of neutrons using a diamond detector
Deuteron energy (MeV) | Main energy of neutrons (MeV) | Main-energy neutron fluence at the diamond position (n/cm2) | The proportion of the low-energy neutrons | |||
|---|---|---|---|---|---|---|
Diamond | 238U fission chamber/associated alpha particle | Diamond (%) | EJ-309 (%) | |||
d–d neutron source | 2.46 | 5.0 | 3.21 × 107 | (3.17 ± 0.11) × 107 | 14.6 | 16.8 |
2.87 | 5.5 | 2.99 × 107 | (2.92 ± 0.11) × 107 | 12.6 | 17.2 | |
6.00 | 8.5 | 3.09 × 107 | (2.90 ± 0.11) × 107 | 25.5 | 23.5 | |
6.98 | 9.5 | 4.06 × 107 | (4.15 ± 0.16) × 107 | 40.8 | 29.2 | |
7.98 | 10.5 | 2.02 × 107 | (2.05 ± 0.08) × 107 | 51.2 | 38.5 | |
d–t neutron source | 0.3 | 14.2 | 3.75 × 108 | (3.62 ± 0.18) × 108 | – | – |