Table 4 Subjective evaluation of TFI compared to 175-mAs-FBP: CT findings.
Tube current–time products (mAs) | Score | ||||
|---|---|---|---|---|---|
10 | 25 | 50 | 75 | 100 | |
Bronchi | 2.3 ± 0.1* | 2.9 ± 0.1 | 3.0 ± 0.1 | 3.0 ± 0.1 | 3.3 ± 0.1* |
Small vessel | 2.6 ± 0.1* | 3.7 ± 0.1* | 3.8 ± 0.1* | 4.0 ± 0.1* | 4.3 ± 0.1* |
Bronchiectasis | 2.9 ± 0.0 | 3.0 ± 0.0 | 3.2 ± 0.0* | 3.1 ± 0.0 | 3.4 ± 0.0* |
Ground-glass Opacity | 2.8 ± 0.1 | 3.2 ± 0.1 | 3.1 ± 0.1 | 3.0 ± 0.1 | 3.2 ± 0.1 |
Reticulation | 2.5 ± 0.1* | 3.2 ± 0.1 | 3.7 ± 0.1* | 3.6 ± 0.1* | 3.7 ± 0.1* |
Nodule | 3.1 ± 0.1 | 3.0 ± 0.1 | 3.0 ± 0.1 | 3.0 ± 0.1 | 3.1 ± 0.1 |
Noise | 4.0 ± 0.1* | 3.0 ± 0.1 | 2.8 ± 0.1 | 2.2 ± 0.1* | 2.0 ± 0.1* |
Streak artifact | 4.0 ± 0.1* | 3.5 ± 0.1 | 2.8 ± 0.1 | 2.3 ± 0.1 | 2.3 ± 0.1 |
Overall image Quality | 2.5 ± 0.1 | 3.4 ± 0.2 | 3.8 ± 0.1* | 3.8 ± 0.1* | 4.0 ± 0.1* |