Table 1 Characteristics of the complementary inverter with carbon contact electrodes.

From: Electrostatically-sprayed carbon electrodes for high performance organic complementary circuits

Vdd (V)

Vsw (V)

Ithrough (A)

Gainmax (V/V)

Ipeak × Vdd (W)

15

7.19

1.28 × 10−6

21.0

1.93 × 10−5

10

4.89

5.19 × 10−7

19.5

5.19 × 10−6

5

2.64

1.11 × 10−7

12.8

5.56 × 10−7