Table 2 Polycyclic aromatic hydrocarbons: Per-puff concentration of e-cigarette vapour emissions, respective method air blanks and Ky1R6F cigarette smoke.

From: Chemical characterisation of the vapour emitted by an e-cigarette using a ceramic wick-based technology

Vapour constituent

Unit

ePod1.0

Cigarette

Percentage reduction (%)

Air blank

BB57

BB18

Ky1R6F

BB57

BB18

Polycyclic aromatic hydrocarbons

Puff count

per consumable

50

50

50

9

-

-

Benzo[a]anthracene

ng puff–1

 < LOD

 < LOD

 < LOD

3.38 ± 0.06

99.9

99.9

Benzo[a]pyrene

ng puff–1

 < LOD

 < LOD

 < LOD

1.63 ± 0.04

99.7

99.7

Benzo[b]fluoranthene

ng puff–1

 < LOD

 < LOD

 < LOD

1.64 ± 0.11

99.5

99.5

Benzo[c]phenanthrene

ng puff–1

 < LOD

 < LOD

 < LOD

0.79 ± 0.02

99.7

99.7

Benzo[j]aceanthrylene

ng puff–1

 < LOD

 < LOD

 < LOD

0.28 ± 0.01

96.9

98.2

Benzo[k]fluoranthene

ng puff–1

 < LOD

 < LOD

 < LOD

0.51 ± 0.02

98.8

98.8

Chrysene

ng puff–1

 < LOQ

 < LOQ

 < LOD

3.40 ± 0.06

99.8

99.9

Cyclopenta[c,d]pyrene

ng puff–1

 < LOD

 < LOD

 < LOD

2.27 ± 0.11

99.8

99.8

Dibenzo[a,h]anthracene

ng puff–1

 < LOD

 < LOD

 < LOD

0.15 ± 0.01

95.7

95.7

Dibenzo[a,e]pyrene

ng puff–1

 < LOD

 < LOD

 < LOD

 < LOQ

NC

NC

Dibenzo[a,h]pyrene

ng puff–1

 < LOD

 < LOD

 < LOD

 < LOQ

NC

NC

Dibenzo[a,i]pyrene

ng puff–1

 < LOD

 < LOD

 < LOD

 < LOQ

NC

NC

Dibenzo[a,l]pyrene

ng puff–1

 < LOD

 < LOD

 < LOD

 < LOQ

NC

NC

Indeno[1,2,3-cd]pyrene

ng puff–1

 < LOD

 < LOD

 < LOD

0.68 ± 0.02

99.3

99.3

5-methylchrysene

ng puff–1

 < LOD

 < LOD

 < LOD

0.02 ± 0.004

92.5

92.5

Naphthalene

ng puff–1

0.04 ± 0.01

0.18 ± 0.08

0.14 ± 0.10

131 ± 4.6

99.9

99.9

Pyrene

ng puff–1

0.10 ± 0.01

0.11 ± 0.01

0.10 ± 0.01

9.34 ± 0.12

98.9

98.9

  1. Values are presented as mean ± standard deviation (n = 5). Percentage reduction of e-cigarette emissions relative to Ky1R6F cigarette smoke. NC not calculated, LOD limit of detection, LOQ limit of quantification. More information about the analytical methods and respective LODs and LOQs are under the Supplementary Information (Tables S1 and S2).