Table 4 Ultrasonic forming parameters of thin sheetmetal without fracture in Micro-USF experiment.

From: Effect of ultrasonic vibration on forming force and forming quality in micro-punching with a flexible punch

Thinsheetmetal(μm)

Die diameter (μm)

Ultrasonic power (%)

Ultrasonic time (s)

10

500–700

50

0–0.3

55

0–0.2

60

0–0.1

20

700

50

0–0.4

55

0–0.2

60

0–0.1

65

0–0.1