Table 4 Comparison of the CFD results (Bq m−3) with those obtained by active and passive measurement techniques at different levels in the closed-door scenario when ACH = 1 (h−1).

From: Measurements and computational fluid dynamics investigation of the indoor radon distribution in a typical naturally ventilated room

Z (cm)

Device

(X,Y) coordinate (Bqm−3)

Center (Bqm−3)

Average (Bqm−3)

A (2.9, 0.1)

B (0.1, 0.1)

C (0.1, 3.9)

D (2.9, 3.9)

20

Alphagaurd

93

109

74

63

91.5

86

RAD7

120

99

82

66

95.8

92

Raduet

88

79

58

65

73

NRPB

77

65

72

59

68

Simulation

224.43

133.41

68.57

54.42

82.35

112

100

Alphagaurd

110

108

61

63

84.6

85

RAD7

119

105

68

61

77.1

86

Raduet

89

92

66

74

80

NRPB

76

66

58

63

65

Simulation

170.7

140.18

51.33

45.3

65.59

95

180

Alphagaurd

RAD7

Raduet

75

95

64

57

73

NRPB

77

80

58

66

69

Simulation

110.12

121.21

52.3

46.23

59.17

79