Table 2 Accuracy of predicted position of maximum strain for each crack length.

From: Deep neural network-based structural health monitoring technique for real-time crack detection and localization using strain gauge sensors

Crack length (mm)

Accuracy (\(\%\))

1

96.6

3

95.5

5

91.8

7

92.5

9

96.3

12

97.3

15

95.4