Table 3 Performance metrics in the testing set for the slices evaluation using the best model found by the Hyperparameter tuning.

From: Contrast phase recognition in liver computer tomography using deep learning

 

Precision

Recall

F1-score

AUC

N

Unenhanced

0.99

0.99

0.99

1

10,757

Arterial

0.98

0.98

0.98

1

10,870

Portal

0.92

0.89

0.89

0.99

11,907

Delayed

0.89

0.93

0.91

0.99

10,803

Average

0.95

0.95

0.95

0.99