Table 3 Results of a multiple linear regression analysis with pattern standard deviation of automated static perimetry* in the worse eye as a dependent variable in patients with primary open-angle glaucoma.
From: Genetic variants associated with glaucomatous visual field loss in primary open-angle glaucoma
Independent variables | Beta† (95% CI) | SE | P value |
|---|---|---|---|
Age, years | − 0.026 to − 0.014 (− 0.056 to 0.029) | 0.021 | 0.23–0.52 |
Male sex | − 1.04 to − 0.74 (− 2.16 to 0.37) | 0.56–0.57 | 0.068–0.19 |
GRS of 5 optic nerve-related genetic variants | 0.65 (0.16–1.15) | 0.25 | 0.0097 |
GRS of 17 IOP-related genetic variants | 0.15 (− 0.064 to 0.36) | 0.11 | 0.17 |