Table 6 Analysis of variance (ANOVA) for the fitted polynomial models (35 and 130 kHz) for DCF removal using US/ANF.

From: Combination of advanced nano-Fenton process and sonication for destruction of diclofenac and variables optimization using response surface method

Response: DCF removal (%)

Df

Sum Sq

Mean Sq

F value

Pr(> F)

35 kHz

First-order

3

1084.5

361.5

93.3796

1.49 × 10–11

Two-way interaction

3

34.07

11.36

2.934

0.05984

Pure quadratic

3

405.93

135.31

34.9519

6.18 × 10–08

Residuals

19

73.55

3.87

  

Lack of fit

5

18.21

3.64

0.9214

0.49565

Pure error

14

55.34

3.95

  

130 kHz

First-order

3

832.42

277.472

548.2421

2.20 × 10–16

Two-way interaction

3

32.61

10.87

21.4771

2.53 × 10–06

Pure quadratic

3

421.56

140.519

277.6433

7.29 × 10–16

Residuals

19

9.62

0.506

  

Lack of fit

5

2.47

0.493

0.9657

0.4712

Pure error

14

7.15

0.511