Table 1 Spatial resolution estimates (mean ± one standard deviation) along the x, y, and z direction extracted from the phase images of the sphere phantom, obtained through sub-sampling the dithered dataset using the values of dx and dy given in the left most columns.

From: Cycloidal-spiral sampling for three-modal x-ray CT flyscans with two-dimensional phase sensitivity

dx (μm)

dy (μm)

Spatial resolution (μm)

x

y

z

0

0

44 ± 7

94 ± 9

48 ± 8

10

10

36 ± 3

60 ± 10

32 ± 6

10

20

40 ± 20

50 ± 10

46 ± 8

10

40

39 ± 10

70 ± 30

34 ± 6

20

10

45 ± 5

31 ± 8

52 ± 5

20

20

35 ± 9

39 ± 7

35 ± 3

20

40

37 ± 9

55 ± 5

54 ± 3

30

30

41 ± 7

56 ± 7

43 ± 5

40

10

54 ± 5

35 ± 2

55 ± 3

40

20

61 ± 5

40 ± 10

45 ± 4

40

40

53 ± 3

60 ± 1

43 ± 1