Table 3 Pressure difference between the true and false lumens for AC and AFC in the FSI simulation.

From: Fluid–structure interaction simulation of visceral perfusion and impact of different cannulation methods on aortic dissection

Type

AC

AFC

Region

CA

SMA

CA

SMA

Flow

FL

TL

Diff

FL

TL

Diff

FL

TL

Diff

FL

TL

Diff

3 L/min

1.19

0.37

0.82

1.18

0.38

0.80

1.10

0.96

0.14

1.10

0.98

0.12

4 L/min

1.79

0.58

1.21

1.79

0.63

1.16

1.81

1.58

0.23

1.81

1.62

0.19

5 L/min

2.64

0.72

1.92

2.63

0.82

1.81

2.73

2.33

0.40

2.73

2.42

0.31

6 L/min

4.08

0.88

3.20

4.09

1.02

3.07

3.86

3.29

0.57

3.85

3.32

0.53

7 L/min

5.54

1.04

4.50

5.53

1.27

4.26

4.88

4.31

0.57

4.88

4.44

0.44