Table 3 Summary of comparisons of different MPPT control algorithms.
Parameter | Irradiance | Output voltage | Output power | MPP algorithm | Actual MPP | Rise time | Efficiency (eq. 13) | Ripple factor |
|---|---|---|---|---|---|---|---|---|
W/m\(^{2}\) | V | Watt | Watt | Watt | s | % | ||
Proposed | 1000 | 69.76 | 244 | 247.4 | 250 | 0.052 | 98.96% | 0.436 |
800 | 62.3 | 194.3 | 197.87 | 200 | 0.43 | 98.9% | 0.53 | |
600 | 54 | 145.6 | 148.92 | 150 | 0.87 | 99.28% | 0.52 | |
ANFIS | 1000 | 69 | 238.7 | 244.62 | 250 | 0.13 | 97.84% | 0.202 |
800 | 61.9 | 192.7 | 196.65 | 200 | 0.45 | 98.3% | 0.08 | |
600 | 53.5 | 143.07 | 146.5 | 150 | 0.85 | 97.66% | 0.05 | |
NN | 1000 | 68.9 | 238 | 244 | 250 | 0.18 | 97.6% | 0.062 |
800 | 61.8 | 191.27 | 196.4 | 200 | 0.489 | 98.2% | 0.03 | |
600 | 53.4 | 142.75 | 145.95 | 150 | 0.892 | 97.3% | 0.01 | |
P &O | 1000 | 69.1 | 240 | 246 | 250 | 0.3 | 98.4% | 0.027 |
800 | 62 | 192.8 | 197 | 200 | 0.6 | 98.4% | 0.01 | |
600 | 53.5 | 143.2 | 146.7 | 150 | 1 | 97.8% | 0.01 |