Table 3 Grid independence test.

From: Influence of inflow directions and setting angle of inlet guide vane on hydraulic performance of an axial-flow pump

 

Impeller only (No. of node of impeller passage)

IGV and impeller (No. of node of IGV passage)

Full component (No. of node of DV passage)

N1

666,773

550,272

571,540

N2

265,681

248,100

256,250

N3

115,260

409,164

114,500

r21

1.359

1.304

1.307

r32

1.321

1.315

1.308

\({\upeta }_{1}/{\upeta }_{1}\)

1.00

0.976

1.043

\({\upeta }_{2}/{\upeta }_{1}\)

0.993

0.975

1.042

\({\upeta }_{3}/{\upeta }_{1}\)

0.972

0.957

1.026

p

3.769

9.199

9.123

\({e}_{ext}^{21}\)

0.00325

0.00014

0.00012

\({\mathrm{GCI}}_{medium}^{32}\)

0.01412

0.00197

0.00178

\({\mathrm{GCI}}_{\mathrm{fine}}^{21}\)

0.00407

0.00017

0.00016