Table 3 Percentage of aerosols dispersed to each location (inside the room, under the doorway, and at the nursing station) after aerosolization.

From: Assessment of aerosol persistence in ICUs via low-cost sensor network and zonal models

ICU

Negative Pressure

Positive Pressure

Neutral Pressure

Inside (%)

Doorway (%)

Nurse Station (%)

Inside (%)

Doorway (%)

Nurse Station (%)

Inside (%)

Doorway (%)

Nurse Station (%)

ICU 1

103.4 ± 0.8

− 2.5 ± 0.5

− 0.9 ± 0.3

101.3 ± 0.9

− 0.3 ± 0.9

− 1.0 ± 0.0

97.5 ± 2.0

2.9 ± 1.8

− 0.5 ± 0.3

ICU 2

N/A

N/A

N/A

94.1 ± 1.9

4.3 ± 1.4

1.6 ± 0.6

86.3 ± 4.2

14.2 ± 1.4

0.6 ± 0.3

ICU 3

101.8 ± 1.3

− 1.2 ± 0.9

− 0.5 ± 0.4

97.5 ± 2.7

6.0 ± 0.1

− 3.5 ± 2.6

95.1 ± 1.5

5.6 ± 1.8

− 0.8 ± 0.5

ICU 4

N/A

N/A

N/A

N/A

N/A

N/A

79.8 ± 2.1

18.5 ± 1.3

1.7 ± 1.0