Table 1 Weight loss test results of MS following 6 h immersion in 5% HCl solution in the absence and occurrence of diverse concentrations of expired Ampicillin drug at varying temperatures.

From: Corrosion inhibition of mild steel in hydrochloric acid solution by the expired Ampicillin drug

C (mM)

25 °C

35 °C

45 °C

55 °C

ν (mpy)

θ

%ηw

ν (mpy)

θ

%ηw

ν (mpy)

θ

%ηw

ν (mpy)

θ

%ηw

0

69.12 ± 1.6

156.37 ± 5.2

526.8 ± 14.8

2342.3 ± 32.9

0.01

22.14 ± 0.3

0.679

67.9

45.63 ± 1.2

0.708

70.8

141.6 ± 4.3

0.731

73.1

82.5 ± 11.3

0.964

96.4

1

20.13 ± 0.2

0.708

70.8

40.94 ± 1.1

0.738

73.8

122.8 ± 4.1

0.766

76.6

73.1 ± 10.3

0.968

96.8

10

17.44 ± 0.2

0.747

74.7

36.24 ± 0.7

0.768

76.8

97.9 ± 2.3

0.814

81.4

72.5 ± 7.6

0.969

96.9

20

16.77 ± 0.1

0.757

75.7

34.89 ± 0.5

0.776

77.6

84.5 ± 1.1

0.839

83.9

75.1 ± 5.5

0.967

96.7

  1. “ ± ” shows the standard deviation of three measurements.