Table 3 Kinetics data for Geeraerd’s model fit parameter and Plan LRV for 2 UV Lamps (bracketed values indicate a 95% confidence interval about the mean, n = 12).

From: Improved disinfection performance for 280 nm LEDs over 254 nm low-pressure UV lamps in community wastewater

Lamp

k (cm2 mJ−1)

Nres Log (MPN-100 mL−1)

Plant LRV Log (MPN-100 mL−1)

RMSE

254 nm LP

0.102 (0.085–0.119)

2.82 (2.58–3.07)

3.31 (2.76–3.87)

0.405

279 nm LED

0.223 (0.173–0.274)

3.61 (3.39–3.84)

0.598