Table 1 Number densities, flow rates, and composition of the inlet flow components in the PFR.

From: Stochastic optimization of a uranium oxide reaction mechanism using plasma flow reactor measurements

 

Analyte

Added oxygen

Carrier gas

\(\hbox {UO}_2\)

\(\hbox {H}_2\)O

\(\hbox {NO}_3\)

\(\hbox {O}_2\)

Ar

n (cm\(^{-3}\))

\(3.48\times 10^{22}\)

\(2.45\times 10^{19}\)

\(2.45\times 10^{19}\)

\({\dot{V}}\) (L/min)

\(2.52\times 10^{-5}\)

0–0.05

1–15.4

Species fraction

\(4.31\times 10^{-3}\)

\(9.87\times 10^{-1}\)

\(8.62\times 10^{-3}\)

1

1

\({\dot{N}}\) (molecules/min)

\(3.78\times 10^{18}\)

\(8.65\times 10^{20}\)

\(7.56\times 10^{18}\)

0–\(1.22 \times 10^{21}\)

(0.25–\(3.77) \times 10^{23}\)