Table 4 Corrosion weight per unit length of different anchor bars for 6 months of corrosion.
From: Performance evolution of prestressing anchor bars in corrosive environments experimental study
pH | Corrosion weight per unit length (g cm−1) | |||||||
|---|---|---|---|---|---|---|---|---|
No prestressing | 24% stress level | 36% stress level | 48% stress level | |||||
Measured value | Average value | Measured value | Average value | Measured value | Average value | Measured value | Average value | |
5.0 | 0.103 | 0.093 | 0.116 | 0.108 | 0.118 | 0.109 | 0.110 | 0.102 |
0.087 | 0.108 | 0.110 | 0.100 | |||||
0.089 | 0.100 | 0.099 | 0.096 | |||||
7.0 | 0.053 | 0.051 | 0.083 | 0.072 | 0.088 | 0.078 | 0.085 | 0.076 |
0.052 | 0.068 | 0.074 | 0.072 | |||||
0.048 | 0.065 | 0.072 | 0.071 | |||||
9.0 | 0.028 | 0.02 | 0.057 | 0.053 | 0.059 | 0.056 | 0.056 | 0.050 |
0.017 | 0.053 | 0.056 | 0.050 | |||||
0.015 | 0.049 | 0.053 | 0.044 | |||||