Table 5 Comparative assessment of the proposed IGTT with reported optimizers for the BCS 500W stack.
From: Fuel-cell parameter estimation based on improved gorilla troops technique
Technique | Best.(10–2) | Mean.(10–2) | Worst.(10–2) | STD |
|---|---|---|---|---|
Proposed IGTT | 1.16977808 | 1.4329 | 2.699 | 0.005359 |
GTT | 1.1698187 | 2.6388 | 7.0539 | 0.016382 |
FFO | 1.6297316 | 3.4934 | 10.8863 | 0.017344 |
SDO | 1.1905119 | 5.9894 | 36.3407 | 0.071129 |
RFO | 2.1226738 | 23.9040 | 153.8797 | 0.308101 |
WOA18 | 37.273 | 256.3700 | 851.7320 | 2.55770 |
ALO27 | 1.1900 | 20.6000 | 60.5200 | 0.1880 |
GOA27 | 1.7100 | 43.8549 | 221.0571 | 67.4693 |
MVO27 | 2.1300 | 5.2500 | 13.5600 | 0.1565 |
STSA49 | 2.1350 | 62.114 | 340.1770 | 0.70331 |
MRFO49 | 3.6830 | 39.1070 | 113.428 | 0.25386 |
EO49 | 1.4620 | 4.6460 | 13.4140 | 0.03633 |
MFO51 | 1.1900 | 4.7800 | 13.5100 | 0.0434 |
SSA52 | 1.6100 | 16.2300 | 47.8000 | 0.1565 |
FMHHO53 | 1.7700 | 37.3710 | 13.4980 | 0.13008 |
MHHO53 | 1.3511 | 24.0670 | 55.45000 | 0.15958 |
HHO53 | 1.5753 | 28.2000 | 42.2330 | 0.13165 |