Table 6 The optimum conditions for chlorophyll a and TOC removal.

From: The effect of the combined system of hydrodynamic cavitation, ozone, and hydrogen peroxide on chlorophyll a and organic substances removal in the raw water

Parameters

pH

Time

Pressure

Flow

Distance

O3

H2O2

EF1

EF2

S/N

Test 5 for chlorophyll a removal

7

60

5

1

25

2

2

98

98.61

39.85

Optimization condition for chlorophyll a removal

5

90

5

1

25

3

2

100

100

40

Test 5 for TOC removal

7

60

5

1

25

2

2

79.5

81

38.08

Optimization condition for TOC removal

5

90

5

1

25

3

2

100

100

40

  1. Significant values are in bold.