Table 1 Metal content of 203Pb elute fractions in ppb (μg/L) and ng as determined by ICP-MS (n = 3).

From: Optimized production, purification, and radiolabeling of the 203Pb/212Pb theranostic pair for nuclear medicine

Metal

Al

Ag

Ca

Fe

Cu

Zn

Pb

Tl

ppb (μg/L)

 One-column method9

168 ± 152

N.S.

568 ± 263

18 ± 11

2.7 ± 1.8

21 ± 4

495 ± 218

58,220 ± 35,392

 This work

100 ± 51

1.4 ± 0.3 (In 8 M HCl elute: 3353 ± 287)

N.S.

29 ± 9

N.S.

14 ± 4

34 ± 6

26 ± 3 (In 8 M HCl elute: 2236 ± 483)

 This work—recycled natTl

N.S.

1.8 ± 0.2

N.S.

18 ± 1

N.S.

26 ± 5

25 ± 8

28 ± 14

ng

 One-column method9

504 ± 456

N.S.

1704 ± 789

54 ± 33

8.1 ± 5.4

63 ± 12

1,485 ± 654

174,660 ± 106,176

 This work

200 ± 102

2.8 ± 0.6 (In 8 M HCl elute: 6706 ± 574)

N.S.

58 ± 18

N.S.

28 ± 8

68 ± 12

52 ± 6 (In 8 M HCl elute: 4472 ± 966)

 This work—recycled natTl

N.S.

3.6 ± 0.4

N.S.

36 ± 2

N.S.

52 ± 10

50 ± 16

56 ± 28

  1. N.S. not significant.