Table 1 Repeatability and Reproducibility Assays.
From: Development of quantitative multiplex RT-qPCR one step assay for detection of hepatitis delta virus
Standard (copies/reaction) | 1st run (Ct) | 2nd run (Ct) | 3rd run (Ct) | Mean | SD ( ±) | CV(%) |
|---|---|---|---|---|---|---|
1 × 105 | 19,722 | 19,811 | 19,853 | 19,80 | 0,07 | 0,34 |
1 × 104 | 22,973 | 23,106 | 23,128 | 23,07 | 0,08 | 0,36 |
1 × 103 | 26,244 | 26,552 | 26,382 | 26,39 | 0,15 | 0,58 |
1 × 102 | 29,691 | 29,788 | 29,872 | 29,78 | 0,09 | 0,30 |
1 × 101 | 33,207 | 33,388 | 33,431 | 33,34 | 0,12 | 0,36 |
5 × 100 | 34,257 | 34,330 | 34,324 | 34,30 | 0,04 | 0,12 |
Slope | − 3,321 | − 3,401 | − 3,373 | – | – | – |
Intercept | 36,288 | 36,749 | 36,639 | – | – | – |
R2 | 0,999 | 0,999 | 0,999 | – | – | – |
Efficiency | 100,04% | 96,78% | 97,89% | – | – | – |