Table 1 Sensitivities and specificities of the Euroarray test system.

From: A retrospective evaluation of the Euroarray STI-11 multiplex system for the detection of eight STI causing agents

Target

True pos

(%)

True neg

(%)

C. trachomatis

34/44

(77)

41/41

(100)

HSV-1

48/50

(96)

45/45

(100)

HSV-2

50/50

(100)

44/44

(100)

M. hominis

48/48

(100)

48/48

(100)

N. gonorrhoeae

45/47

(96)

25/26

(96)

T. pallidum

9/11

(82)

18/18

(100)

U. parvum

46/46

(100)

44/44

(100)

U. urealyticum

49/49

(100)

44/45

(98)

  1. True positivity (pos.) and true negativity (neg.) rates of the EA refer to the results of the respective reference methods applied in this study or (in cases of discrepancies between the EA and the reference method) to the results of an independent decisive third test.