Table 2 Weight loss (WL), corrosion rate (v), surface coverage (θ), and inhibition efficiency (ηWL) for T95 corrosion in 15 wt% HCl solution in the absence and presence of various concentrations of potassium iodide (KI) and sodium dodecyl sulphate (SDS) at different temperatures from weight loss technique.
Conc | WL ± S.D (g) | (v ± S.D) (mm/y) | θ | ηWL% | WL ± S.D (g) | (v ± S.D) (mm/y) | θ | ηWL% |
|---|---|---|---|---|---|---|---|---|
60 °C | 70 °C | |||||||
Blank | 0.15 ± 0.04 | 26.20 ± 0.17 | – | – | 0.35 ± 0.02 | 60.20 ± 3.47 | – | – |
1 mM KI | 0.10 ± 0.01 | 17.00 ± 0.17 | 0.35 | 35 | 0.24 ± 0.02 | 41.63 ± 0.17 | 0.32 | 32 |
3 mM KI | 0.11 ± 0.01 | 18.22 ± 2.26 | 0.31 | 31 | 0.25 ± 0.20 | 43.54 ± 2.26 | 0.28 | 28 |
5 mM KI | 0.11 ± 0.02 | 19.43 ± 3.99 | 0.26 | 26 | 0.27 ± 0.01 | 46.14 ± 0.87 | 0.23 | 23 |
1 mM SDS | 0.11 ± 0.01 | 18.22 ± 1.21 | 0.30 | 30 | 0.26 ± 0.01 | 44.24 ± 1.73 | 0.26 | 26 |
3 mM SDS | 0.12 ± 0.01 | 20.30 ± 0.52 | 0.22 | 22 | 0.28 ± 0.08 | 48.75 ± 4.39 | 0.19 | 19 |
5 mM SDS | 0.13 ± 0.02 | 22.21 ± 0.35 | 0.15 | 15 | 0.30 ± 0.02 | 51.18 ± 3.64 | 0.15 | 15 |
80 °C | 90 °C | |||||||
Blank | 0.61 ± 0.01 | 106.17 ± 1.73 | – | – | 0.86 ± 0.05 | 149.54 ± 8.67 | – | – |
1 mM KI | 0.43 ± 0.06 | 74.60 ± 6.41 | 0.30 | 30 | 0.62 ± 0.06 | 107.56 ± 9.41 | 0.28 | 28 |
3 mM KI | 0.45 ± 0.06 | 78.07 ± 5.20 | 0.26 | 26 | 0.67 ± 0.02 | 116.23 ± 3.47 | 0.23 | 23 |
5 mM KI | 0.49 ± 0.03 | 85.00 ± 5.20 | 0.20 | 20 | 0.71 ± 0.02 | 123.17 ± 3.47 | 0.17 | 17 |
1 mM SDS | 0.48 ± 0.03 | 83.27 ± 5.20 | 0.22 | 22 | 0.67 ± 0.01 | 116.23 ± 1.73 | 0.22 | 22 |
3 mM SDS | 0.53 ± 0.08 | 91.94 ± 7.88 | 0.13 | 13 | 0.69 ± 0.01 | 119.70 ± 1.73 | 0.19 | 19 |
5 mM SDS | 0.52 ± 0.05 | 90.21 ± 8.67 | 0.15 | 15 | 0.71 ± 0.08 | 123.17 ± 9.88 | 0.17 | 17 |