Table 1 Specifications and attiributes of the proposed rectifier.

From: A multiband SSr diode RF rectifier with an improved frequency ratio for biomedical wireless applications

Parameters

Width/Length

(mm)

Parameters

Width/Length

(mm)

Parameters

Width/Length

(mm)

TL

0.6/1.5

TL12

0.6/3.5

TL24

0.6/3.4

TL1

0.6/3.0

TL13

0.6/5.0

TL25

0.6/3.75

TL2

1.0/1.3

TL14

0.6/1.0

TL26

0.6/5.5

TL3

0.6/5.8

TL15

1.0/4.7

TL27

0.6/3.85

TL4

0.6/3.5

TL16

0.6/3.4

TL28

0.6/5.5

TL5

0.6/3.65

TL17

0.6/1.0

TL29

0.6/1.5

TL6

0.6/1.6

TL18

0.6/1.6

TL30

0.6/4.6

TL7

0.6/1.0

TL19

0.6/1.3

TL31

0.6/1.5

TL8

0.6/1.5

TL20

0.6/4.0

TL32

0.6/1.0

TL9

0.6/2.0

TL21

0.6/2.0

TL33

0.6/1.6

TL10

0.6/9.0

TL22

1.0/0.8

b/a

20.7/19.3

TL11

0.6/5.5

TL23

1.0/0.7

Lr1/Lr2

0.6/2.2

Parameters

\(W_c\)/R (mm)

(\(\theta\) = 90\(^o\))

Parameters

Values/Values

(nH)

Parameters

Values/Unit

MC

0.6/1.0

\(L_{a}\)/\(L_{b}\)

1.0/1.0

Lr3/Lr4

2.1/0.6

MC4

0.6/0.5

\(L_{c}\)/\(L_{d}\)

5.1/5.1

C1 (pF)/\(R_{L}\)(k\(\Omega\))

330/5

  1. [Microstrip curve bend (MC) = W\(_c\), R, \(\theta\)], [Transmission line (TL) = W, L], [Radial stub length = Lr].
  2. MC = MC1 = MC2 = MC3 = MC6, MC4 = MC5 = MC7, C1 = C2
  3. Impedance Transformer (IT\(_x\)) MN: TL7, TL17, TL20, and TL32.
  4. (All units are in mm, Diagram not up to scale).