Table 8 The results using HOMER for diesel generator and PV panels.
Quantity | Value | Units |
|---|---|---|
Diesel generator(Generic 25kW fixed capacity) | 9.769 | kWh/year |
Diesel generator (Generic 25kW fixed capacity) | 15,024.51 | $ |
NAS Battery | 1 | Unit |
NAS Battery | 380,000.00 | $ |
System inverter | 600.00 | $ |
Total fuel consumed | 3.956 | L |
Average fuel per day | 10.8 | L/day |
Average fuel per hour | 0.452 | L/hour |
Carbon dioxide | 10.357 | Kg/year |
Carbon monoxide | 64.6 | Kg/year |
Unburned hydrocarbons | 2.85 | Kg/year |
Particulate matter | 0.388 | Kg/year |
Sulfur dioxide | 25.4 | Kg/year |
Nitrogen oxides | 60.8 | Kg/year |