Table 2 Offline detection accuracy of the algorithm.
From: Brain-computer interface for robot control with eye artifacts for assistive applications
Experiment | Blink | Look left | Look right | |||
|---|---|---|---|---|---|---|
Accuracy | \(\%\) | Accuracy | \(\%\) | Accuracy | \(\%\) | |
15/06/22 | 206/299 | 90.0 | 11/13 | 84.6 | 14/18 | 77.8 |
16/06/22 | 164/208 | 78.8 | 25/27 | 92.6 | 22/28 | 78.6 |
28/06/22 | 88/94 | 93.6 | 47/49 | 95.9 | 49/50 | 98 |
29/06/22 | 102/102 | 100 | 58/59 | 98.3 | 68/71 | 95.8 |
20/07/22 | 111/137 | 81.0 | 72/74 | 97.3 | 49/62 | 79 |
22/07/22 | 137/141 | 97.2 | 68/68 | 100 | 54/67 | 80.6 |
Overall | 808/911 | 88.7 | 281/290 | 96.9 | 256/296 | 86.5 |