Table 3 Fuzzy control rules.
Input | Output | |||
|---|---|---|---|---|
Time of day | Sensor data | Temperature | Irrigation intensity | |
1 | Night | Dry | Cold | Medium |
2 | Night | Dry | Moderate | Medium |
3 | Night | Dry | Hot | High |
4 | Night | Wet | Cold | Low |
5 | Night | Wet | Moderate | Low |
6 | Night | Wet | Hot | Low |
7 | Day | Dry | Cold | Low |
8 | Day | Dry | Moderate | Low |
9 | Day | Dry | Hot | Low |
10 | Day | Wet | Cold | Low |
11 | day | wet | moderate | Low |
12 | Day | Wet | Hot | Low |
13 | Night | Dry | Cold | Medium |
14 | Night | Dry | Moderate | High |
15 | Night | Dry | Hot | High |
16 | Night | Wet | Cold | Low |
17 | Night | Wet | Moderate | Low |
18 | Night | Wet | Hot | Low |