Table 9 The maximum deformation of front row piles under different internal friction angles.

From: Sensitivity analysis of counterweight double-row pile deformation to weak stratum parameters

Internal friction angle φ/(◦)

2

3

4

5

6

Maximum deformation /mm

42.87

41.05

39.57

38.08

37.29