Table 3 Machine parameter.

From: Modified SVPWM technique for CMV reduction in asymmetrical dual three phase induction machine drive

Stator resistance (\(R_{s1}, R_{s2} \))

\(2.19\Omega \)

Rotor resistance (\(R_{r}\))

\( 4.1 \Omega \)

Stator leakage inductance (\(L_{ls}\))

0.015H

Rotor leakage inductance (\(L_{lr}\))

0.015H

Magnetizing inductance (\(L_m\))

0.119H

No. of pole pairs (p)

3

Moment of inertia(J)

\(0.001 kgm^2\)