Table 2 The E-field power variations at T-junctions.

From: Partitioning surface wave propagation on reconfigurable porous plane

Model

h (mm)

Point 4\(^\S \)

Points D5/U5 (Ave.) (in dB)

Insertion Loss incurred (in dB)\({\,}^\ddag \)

Straight path

2.0

0

− 0.28

0.28

90\(^{\circ }\)-bend

1.5

0

− 5.55

5.55

90\(^{\circ }\)-bend

2.0

0

− 3.11

3.11

90\(^{\circ }\)-bend

2.5

0

− 3.63

3.63

Junction 1

2.0

0

− 20.56

17.75

Junction 2

2.0

0

− 6.86

3.75

Junction 3

2.0

0

− 6.18

3.07

Junction 4

2.0

0

− 10.62

7.51

  1. \({\,}^\S \)The value at the reference Point 4 is normalized to 0 dB in each pathway.