Table 2 The E-field power variations at T-junctions.
From: Partitioning surface wave propagation on reconfigurable porous plane
Model | h (mm) | Point 4\(^\S \) | Points D5/U5 (Ave.) (in dB) | Insertion Loss incurred (in dB)\({\,}^\ddag \) |
|---|---|---|---|---|
Straight path | 2.0 | 0 | − 0.28 | 0.28 |
90\(^{\circ }\)-bend | 1.5 | 0 | − 5.55 | 5.55 |
90\(^{\circ }\)-bend | 2.0 | 0 | − 3.11 | 3.11 |
90\(^{\circ }\)-bend | 2.5 | 0 | − 3.63 | 3.63 |
Junction 1 | 2.0 | 0 | − 20.56 | 17.75 |
Junction 2 | 2.0 | 0 | − 6.86 | 3.75 |
Junction 3 | 2.0 | 0 | − 6.18 | 3.07 |
Junction 4 | 2.0 | 0 | − 10.62 | 7.51 |