Table 6 Economical and technical results from the proposed algorithms for all configurations.

From: Techno-economic optimization for isolated hybrid PV/wind/battery/diesel generator microgrid using improved salp swarm algorithm

MS

Algorithm

COE

($/kWh)

NPC

($)

LPSP

REF

(%)

AD

(Day)

PV/WT/BESU/DG

ISSA

0.2109

376,063.8

0.04

96.0655

1.5291

SSA

0.2245

400,358.9

0.0382

96.3846

1.5065

ALO

0.2407

429,279

0.04

96.0002

1.5181

DA

0.3385

603,819.7

0.04

97.8808

1.4673

MFO

0.3549

632,910.7

0.039

96.5101

1.5006

PV/BESU/DG

ISSA

0.2748

490,099

0.06

95

1.5291

SSA

0.2865

510,978.2

0.0583

95

1.5291

ALO

0.3297

587,986.8

0.06

96.0075

1.5169

DA

0.3637

648,693.7

0.0479

95

1.5291

MFO

0.3917

698,656.4

0.0524

94.9988

1.4488

WT/BESU/DG

ISSA

0.2080

371,038.8

0.0388

90

1.3928

SSA

0.2121

378,252.6

0.0486

90

1.273

ALO

0.2160

385,178.6

0.0474

90.0004

1.2718

DA

0.2366

421,958.7

0.05

89.9989

1.177

MFO

0.2340

417,351.4

0.0498

91.1017

1.2078