Table 1 PEM fuel cell stack design parameters.

From: Implementation of high step-up power converter for fuel cell application with hybrid MPPT controller

Variables

Values

Utilized rated PEMFS power

6.0 kW

Applied voltage constraints of PEMFS (VMPP)

45.01 V

Selected rated PEMFS current (IMPP)

133.329A

Openly connected PEMFS voltage (VOC)

65.0 V

Oxygen generated the limited pressure in PEMFS

1.0 bar

Hydrogen generated the limited pressure in PEMFS

1.50 bar

Selected cells for the design of PEMFS (N)

65.00

Fundamental air flow in cell (Ipm)

512.02

Applied gas flow constant (R)

84.013 [J•mol-1•K−1]

Selected faraday parameter (F)

95,117.444 [C•mol−1]

Oxygen reaction rate

19.14%

Reaction of hydrogen

99.57%

The completed reaction of H2

98.991%

The oxygen reaction rate in the fuel stack

60.8%

Fuel stack tested working temperature

335 K