Table 1 PEM fuel cell stack design parameters.
From: Implementation of high step-up power converter for fuel cell application with hybrid MPPT controller
Variables | Values |
|---|---|
Utilized rated PEMFS power | 6.0Â kW |
Applied voltage constraints of PEMFS (VMPP) | 45.01Â V |
Selected rated PEMFS current (IMPP) | 133.329A |
Openly connected PEMFS voltage (VOC) | 65.0Â V |
Oxygen generated the limited pressure in PEMFS | 1.0Â bar |
Hydrogen generated the limited pressure in PEMFS | 1.50Â bar |
Selected cells for the design of PEMFS (N) | 65.00 |
Fundamental air flow in cell (Ipm) | 512.02 |
Applied gas flow constant (R) | 84.013 [J•mol-1•K−1] |
Selected faraday parameter (F) | 95,117.444 [C•mol−1] |
Oxygen reaction rate | 19.14% |
Reaction of hydrogen | 99.57% |
The completed reaction of H2 | 98.991% |
The oxygen reaction rate in the fuel stack | 60.8% |
Fuel stack tested working temperature | 335Â K |