Table 4 Suction flow rates (SFR) and pressures (SP) comparison of the ejector at a motive flow rate of 1.45 GPM at different drag reducing polymers concentrations (0, 50 and 100 ppm) and different suction valve capacities (SVC).

From: Optimizing jet pump efficiency via drag reducing polymers and enhanced efficiency definitions

Motive Flow Rate (GPM)

SVC (%)

SFR (GPM)

SP (kg/cm2)

0 (PPM)

50 (PPM)

100 (PPM)

0 (PPM)

50 (PPM)

100 (PPM)

1.45

100

2.9

3.8

3.83

 − 0.1

 − 0.11

 − 0.11

1.45

90

2.85

3.75

3.78

 − 0.1

 − 0.12

 − 0.12

1.45

80

2.79

3.6

3.64

 − 0.11

 − 0.13

 − 0.13

1.45

70

2.6

3.2

3.49

 − 0.14

 − 0.18

 − 0.18

1.45

60

2.3

2.5

3.1

 − 0.19

 − 0.21

 − 0.21

1.45

50

1.79

1.9

2.6

 − 0.26

 − 0.3

 − 0.3

1.45

40

1.1

1.1

1.7

 − 0.34

 − 0.45

 − 0.45

1.45

30

0.25

0

0.7

 − 0.45

 − 0.525

 − 0.53

1.45

20

0

0

0

 − 0.5

 − 0.58

 − 0.58

1.45

10

0

0

0

 − 0.5

 − 0.6

 − 0.6