Table 5 Comprehensive comparison between the different cases efficiencies at different motive flow rates (1 and 1.45 GPM) and DRPs concentrations (0, 50 and 100 ppm) at fully opened suction control valve.
From: Optimizing jet pump efficiency via drag reducing polymers and enhanced efficiency definitions
Motive flow rate (GPM) | Concentration (PPM) | SVC (%) | ηEX (%) | ηAN1 (%) | ηAN2 (%) | ηHR (%) |
|---|---|---|---|---|---|---|
1.45 | 100 | 100 | 26.69 | 63.58 | 30.51 | 35.3 |
1.45 | 50 | 100 | 25.33 | 62.7 | 29.67 | 34.59 |
1.45 | 0 | 100 | 13.82 | 40.03 | 9.203 | 17.71 |
1 | 100 | 100 | 30.99 | 80.72 | 46.97 | 49.86 |
1 | 50 | 100 | 24.61 | 71.07 | 37.67 | 41.49 |
1 | 0 | 100 | 6.56 | 46.58 | 14.83 | 22.29 |