Table 7 Comparative study of the HPSQB topology with ref19.

From: Extendable high gain low current/high pulse modified quadratic–SEPIC converter for water treatment applications

Parameters

Topology

Duty cycle, D = 0.5

Gain, Gv

10

20

30

40

50

Number of Multiplier cell, M

Proposed converter

1

2

3

4

5

Ref19

4

9

14

19

24

Total component count

Proposed converter

16

20

24

28

32

Ref19

20

40

60

80

100

Parameters

Topology

Total component count = 16

Gain, Gv

8

10

16

20

Duty cycle, D

Proposed converter

0.4

0.5

0.6

0.64

Ref19

0.5

0.6

0.75

0.8

Parameters

Topology

Total component count = 16, Duty cycle = 0.5

Output voltage, Vo (kV)

1

2

5

10

Input voltage, Vg, (V)

Proposed converter

100

200

500

1000

Ref19

125

200

625

1250