Table 1 Summary of numerical cases with stent deployment and blood vessel tapering ratios.
From: Haemodynamics of stent-mounted neural interfaces in tapered and deformed blood vessels
Case no | Features | Stent deployment ratio (a) | Vessel tapering ratio (b) |
|---|---|---|---|
1 | Control | 1 | 1:1 |
2 | Slightly deformed | 1.05 | 1:1 |
3 | Deformed | 1.1 | 1:1 |
4 | Slightly tapered | 1.1 | 1:1.1 |
5 | Tapered | 1.1 | 1:1.2 |
6 | Sheep-specific | – | – |
7 | Sheep-specific | – | – |
8 | Sheep-specific | – | – |