Table 2 Orthogonal test scheme and results.

From: Study on the effect of different high-voltage electric field polarization process parameters on the vitality of dried chili pepper seeds

Run

Output voltage X1/kV

Polarisation time X2/s

Seed conductivity Y/[uS/(cm g)]

1

10

20

198.21

2

9.17157

30

189.66

3

12

44.1421

185.25

4

12

30

158.22

5

12

30

166.19

6

12

30

155.58

7

12

30

157.81

8

12

30

161.79

9

14

40

195.84

10

10

40

172.17

11

12

15.8579

188.66

12

14

20

175.64

13

14.8284

30

180.89