Table 1 Test parameter setting.
From: Spectral band selection and ANIMR-GAN for high-performance multispectral coal gangue classification
Test parameter | Value |
|---|---|
Image input type | RGB of heat map |
size of input | 200 × 200, 100 × 100, 50 × 50 |
Number of images per batch | 32 |
The exponential decay rate of Adam β1 | 0.8 |
The exponential decay rate of Adam β2 | 0.999 |
Adam parameters ε | 10–7 |
learning rate | 10–4 |
Number of pre-trained rounds | 10 |