Table 6 Pullout test results of different borehole depths in rock tunnel.
Depth (mm) | Peak force (kN) | Failure mode | |
|---|---|---|---|
New bolt | Right threaded bolt | ||
800 | 142.2 | 112.5 | Resin failure |
1200 | 148.0 | 115.5 | |
2000 | 162.9 | 125.3 | |
Depth (mm) | Peak force (kN) | Failure mode | |
|---|---|---|---|
New bolt | Right threaded bolt | ||
800 | 142.2 | 112.5 | Resin failure |
1200 | 148.0 | 115.5 | |
2000 | 162.9 | 125.3 | |